five kinds of blood coagulation analyzer immunological method

 Blood coagulation analyzer referred to as “blood clots device, in blood clotting immunological method in the analyzer of purification for material as the antigen, corresponding antibody preparation, then use the antigen antibody response to be seized for qualitative and quantitative determination. Commonly used method have five:
First, blood coagulation analyzer rockets electrophoresis
In certain electric field, gel to support within the things their corresponding antibody detection was formed by the combination of a “rocket peak”, the rockets the height of the peak is proportional to its content, by means of measuring the high peak and compare with standard quantitatively determined. In this operation complex, less clinical application.
Second, blood coagulation analyzer two-way immune electrophoresis
Through the level and vertical two direction electrophoretic will some molecular structure of abnormal blood clot separation.

Third, blood coagulation analyzer ELISA test (ELISA)
YongMei standard antigen and antibody and were seized on the antigen reaction, after washing to remove not combination of antigen or antibodies and the specimens interfering substances, leaving fixed in wall antigen antibody complex, and then join the enzyme substrates and color of the original material, the reaction that produces the non-ferrous material, standard instrument determination, the color depth and were seized in the concentration ratio relations. The high sensitivity, the specific strong, has used in many stop bleeding, thrombus composition detection.
Fourth,semi-auto blood coagulation analyzer immune diffusion method
Will be seized and corresponding antibodies in certain media union, determine the precipitation of the size of the ring, and compare with standard, the calculation of the concentration of the articles to be tested. In this operation is simple, do not need special equipment, but too time consuming, and the sensitivity is not high, is only suitable for content is higher blood coagulation factor of blood clots analyzer test.
Fifth, blood coagulation analyzer immune than turbidity method
Will be seized and its corresponding antibody a complex mixture, which generate enough precipitation grain, through the transmission than muddy or scattering determined than polluted. In this operation is simple, accuracy, good, facilitate automation.
Article: from perlong medical (http://www.pl999.net)
Attention: if you want to copy this article , you must attach the website.

N-end brain natriuretic peptide (BNP with three different items)

N-end brain natriuretic peptide also called NT-proBNP fast kits , for heart failure detection is an important examination indexes. BNP also known as BNP said the b-type natriuretic peptide, myocardial cells first synthesis of 108 amino acids BNP original, called proBNP (BNP precursor).

By heart muscle cells in the stimulation (for example, myocardial cell tensile), proBNP protease role in the following solutions for N-end brain natriuretic peptide (amino-terminal-proBNP or N t-proBNP) and biological activity hormone BNP. Two kinds of peptides have released into the blood circulating. Both source and waiting for the same Moore secretion.

Perlong medical equipment expert analysis, in the clinical, heart failure diagnosis from the point of the BNP and N-brain natriuretic peptide is no different. But there are no difference is impossible to statistics to the analysis of the two small differences. BNP and N-end brain natriuretic peptide tests in the diagnosis of acute and chronic HF with high diagnostic accuracy and has high correlation.

The removal of the body in different ways: the removal of the BNP mainly through and natriuretic peptides clear receptor (NPR-C) combined with and then was the swallow and lysosome degradation, and only a small amount of BNP through the kidney removed, when renal loss, neutral peptide chain enzymes (NEP) also can open the BNP ring structures and it cleared; N-end brain natriuretic peptide clear is the only way to glomerular filtration, kidney appears to lack the N-brain natriuretic peptide metabolic enormous influence.

Second, half life different: BNP’s half-life is 22 minutes, and N-end brain natriuretic peptide half-life for 120 minutes. From the view point of clinical inspection, N-end brain natriuretic peptide in vitro are relatively stable, bring convenience to the test, but from clinical application point of view, more short half-life BNP more timely response patients condition changes, beneficial to the clinical monitoring the efficacy of treatment, the better to clinical application value.

Molecular structure is different: the molecular structure of the BNP there is a very important disulfide key connections consist of ring structures, but with natriuretic peptides receptors play biology active role; Nt proBNP medical test kits for a amylose structure, is losing biological activity of amino acids segment.

Two kinds of peptides have released into the blood circulating. Both source and waiting for the same Moore secretion. So, in theory, detection and N-the BNP brain natriuretic peptide clinical application results are the same. And from years of clinical results speaking, there is not much difference.
Article: from perlong medical (http://www.pl999.net)
Attention: if you want to copy this article , you must attach the website.

Siemens medical X-ray machine how many | PL series offer medical X-ray machine price

Medical X-ray machine with the development of science and technology is no longer had the simple X-ray equipment, today’s medical X-ray machine has not only high frequency rays design, also have a digital instrument, play a variety of functions, add luster for radiologists, give patients bring hope of recovery.

The world famousmedical X-ray machine brand such as Siemens medical X-ray machine, home also has can on quality the comparable brand, that is perlong medical treatment. Siemens medical X-ray machine offer how much, you can ask the agent or by any other means of Siemens get, the medical perlong medical X-ray machine offer you only need advice website online customer service can get, very convenient.
Perlong medical PL series medical X-ray machine by vast customers love, and is the first choice of all hospitals purchasing medical X-ray machine brand.

 

 

Perlong medical–high frequency digital medical X-ray machine PLD6800

This a medical X-ray machine is single sheet tube X-ray machine, cover an area of an area small, simple operation, adapt to host range, high power, high frequency inverter, image is clear and other characteristics, can realize the integration of the shooting. As for medical X-ray machine, and have good control systems, is domestic gastrointestinal machine the authority X-ray machine. Not only that, this a medical X-ray machine also has excellent performance, multi-function diagnosis bed bed body system.
If you would like to ask more about perlong lh-pl series of medical X-ray machine how much the price of related questions, you can consult our online customer service.
Article: from perlong medical (http://www.pl999.net)
Attention: if you want to copy this article , you must attach the website.

Urine analyzer quality control reagents and device

No matter or urine analyzer urine dreg analyzer medical equipment is no substitute for urinalysis, they can only as a screening test. Because urine analyzer can’t observation are found in the urine of red, white, epithelial cells, tube type, macrophages, tumor cells, bacteria, sperm, crystallization visible part, even urine ten or eleven analyzer to red, white examination is limited to chemical examination also, within the scope of urine analyzer and by many factors of interference, and have a certain gap between the actual microscopic, and electrolyte analyzer similar therefore, when urine analyzer abnormal test results should be combined with the microscope examination report results, and with microscope eventuate, because the visible part of the kidneys and urinary tract disease diagnosis and differential diagnosis, the severity of the disease prognosis and has an important function, should not be ignored.

A, strictly according to the requirements of the operation
1. Strictly according to manufacturer asks to install, use and maintenance.
2. Every day before specimen with determination with monitoring instrument calibration performance, use the school inspection with should pay attention to: (1) reagent frame must bring clean, dry; (2) with the inspection shall not dip urine or dips in water; (3) not a hand calibration belt; (4) should be kept in check with special box, avoid light moistureproof; (5) instrument to check when the results of the determination and forecast with not when, should again with another check belt (reference check belt) to test. Calibration unqualified instruments are not permitted to use.
Second, quality with artificial urine in quality control
After startup, when calibration take the determination results when the prescribed scope, then use of the quality manual urine dipsticks method. The results accord with the urine samples again,
Because human urine of chemical composition of natural urine as always, sometimes with larger error, so the conditions permit, shall be in normal for the preparation of urine, add all relevant component of urine that quality. Also can use to control the artificial urine technical personnel technology assessment, and is about to reference urine and quarantine inspection with urine specimen, single-blind study, the determination results and target value in a “+” or a “+” lack of qualified, but the target value of a “+” and “” who was convicted of unqualified, measuring error in the “2 +” above the unqualified should help to find reason and make correct three urine chemistry analyzer, should be combined and microscopic.
Article: from perlong medical (http://www.pl999.net)
Attention: if you want to copy this article , you must attach the website.

Chinese five classification automatic dual channel blood analyzer which brand is of good quality

 

Mentioned medical examination, it’s hard not to mention five classification blood analyzer. Domestic five classification automatic dual channel blood instrument which brand is of good quality? This is the hospital medical branch, the sterilization of buyers are very concerned about the problem. Here we recommend you to a brand, perlong medical treatment.

Perlong medical is domestic blood corpuscle count five classification is brand, is senior medical equipment manufacturers, not only engaged in medical device manufacturing, and also engaged in medical equipment sales industry, with its professional research and development equipment group and powerful financial support.

Choose instrument, is not only choose quality, but also choose services. Perlong medical have their own after-sales teams to ensure you from buying to use to maintain, be service for you, let you buy relieved, with worry.

 

Article : From Perlong medical (http://www.pl999.net/)
Attention:If you want to copy, please attach the website.

Medical X-ray instrument of development

X-ray instrument was originally x-rays medical equipment to a kind of outspread application, common x-rays can be called plane perspective, is to X-ray after objects to the absorption of the rays in the superposition projection on film, object is a reflection of the before and after not to come out, the doctor is according to the human anatomy knowledge imagine the hierarchical relationships. But sometimes have to know the relationship between before and after the object, and then from the perspective of the other to shoot a or a few pieces of film, in order to confirm the doctor imagine three-dimensional form. This kind of technology, called “tomography”. But because of the shadow of mutual keep out, sometimes want to take a lot of Angle, and three-dimensional concept can only be built in deduce the imagination. This is the first X-ray machine.

How to an objective evaluation of the quality of the images in overseas is already taken seriously and had fairly of further research. Same with other radiological diagnosis, our country in introducing X-ray diagnosis instrument technology and did not do it at the same time introduce X-ray equipment checking instrument maintenance technology. But the recent ten years, the medical profession some work in the first line of insight to gradually to radiation diagnosis especially X-ray diagnosis image quality evaluation instrument technology seriously rise. Its main show is the introduction of image quality testing equipment, the quality of images, and made it quite results.

 

Article : From Perlong medical (http://www.pl999.net/)
Attention:If you want to copy, please attach the website.

Applications of Pet X-ray machine

Pet X-ray machine is using the X-ray perspective function, on the pet body parts, organization of imaging, mri, a kind of X-ray machine equipment.
Pet X-ray machine can adjust the image quality and can be in AV, USB output equipment adjust image effect, as the image in the best effect can store took pictures, can always calls, and computer connected to the printer output, save wash pieces and costs. In each big pet hospital has been widely used.
application
Pet X-ray machine can be used in pet each system and parts of X-ray diagnosis, such as pet can check the lungs have inflammation or tumor metastasis, the digestive tract have foreign bodies (bone, small toys, stone etc), the puppy intussusception, fracture, disc herniation, hip dysplasia, bladder calculus, kidney stones, etc.
Pet X-ray machine in the pet of the application of the respiratory system: pet X-ray machine can be used to diagnose the pet tracheal form and lung infection. Lung inflammation in the high frequency in pet X-ray machine performance for white patch or YunXuZhuang, serious can appear chunks of white area. Dogs and cats in trauma, was a big dog bites and penetrating injury, often chest will be bit wear or rib fracture, cause chest leakage, change of the chest negative state to cause respiratory difficulty, at this time will see the chest appeared chunks of white image, if appear emphysema, is inX-ray images show black.
Article: from perlong medical (http://www.pl999.net)
Attention: if you want to copy this article , you must attach the website.

Applications of Pet X-ray machine

Pet X-ray machine is using the X-ray perspective function, on the pet body parts, organization of imaging, mri, a kind of X-ray machine equipment.
Pet X-ray machine can adjust the image quality and can be in AV, USB output equipment adjust image effect, as the image in the best effect can store took pictures, can always calls, and computer connected to the printer output, save wash pieces and costs. In each big pet hospital has been widely used.
application
Pet X-ray machine can be used in pet each system and parts of X-ray diagnosis, such as pet can check the lungs have inflammation or tumor metastasis, the digestive tract have foreign bodies (bone, small toys, stone etc), the puppy intussusception, fracture, disc herniation, hip dysplasia, bladder calculus, kidney stones, etc.
Pet X-ray machine in the pet of the application of the respiratory system: pet X-ray machine can be used to diagnose the pet tracheal form and lung infection. Lung inflammation in the high frequency in pet X-ray machine performance for white patch or YunXuZhuang, serious can appear chunks of white area. Dogs and cats in trauma, was a big dog bites and penetrating injury, often chest will be bit wear or rib fracture, cause chest leakage, change of the chest negative state to cause respiratory difficulty, at this time will see the chest appeared chunks of white image, if appear emphysema, is inX-ray images show black.
Article: from perlong medical (http://www.pl999.net)
Attention: if you want to copy this article , you must attach the website.

Electrolyte analyzer maintenance and troubleshooting

Perlong medical equipment expert analysis electrolyte analyzer maintenance and troubleshooting.
First, the medical equipment electrolyte analyzer maintenance
1 and electrode system maintenance
2, the flow system maintenance
A, flow maintenance most instruments have instrument maintenance program flow, can according to maintenance procedure for maintenance work. When flow maintains the program ended, shall be of the instrument calibration.
B, and the flow cleaning work every day end before the shutdown, to clean the pipeline. Instrument into the flow procedures for cleaning, inhaled or injected cleaning solution, to the egg or distilled water flow rinse, repeat 2? 3. After washing, shall be of the instrument calibration.
Second, medical equipment electrolyte analyzer daily maintenance
Instrument maintenance should according to the instructions of the demands of, daily maintenance, weekly maintenance, maintenance downtime and half a year.
Third, medical equipment electrolyte analyzer common fault and its elimination method
Some common faults, causes and ruled out the method is as follows.
Pipeline jams easily blocked place mainly has four parts, namely the sampling needle and air detector part, electrode cavity and end, mixer part of the front part of the liquid pipe handle, and blocking.
Article: from perlong medical (http://www.pl999.net)
Attention: if you want to copy this article , you must attach the website.

Fully automatic intelligent blood analyzer brands | fully automatic intelligent blood analyzer manufacturers | Fully automatic intelligent blood analyzer prices

Fully automatic intelligent blood analyzer is a new model in the blood count instrument market , as a professional fully automatic intelligent blood count instrument brand-perlong medical, specializing in the production of the blood corpuscle count instrument for nearly 20 years, good quality trustworthy!

 

Perlong Medical—XFA 6000 Intellgient hematology analyzer

If you want to understand the full automatic intelligent blood count instrument brands /prices and manufacturers,welcome your consultation I stand online customer service, believe that you will get a satisfactory answer!

Even if it is fully automatic intelligent blood count instrument does not mean when using can be completely leave behind, or to follow certain rules of use, if meet the problem, can consult after-sale, consultation and technical personnel, of course, you can also himself out, to provide you with the small make up a few yourself out good method.

First, counting on the high side, here refers to the overall on the high side, not at the special case, one or several projects at a time, or a group of specimen inside always on the high side, so the analysis of the particularity of specimen crowd. For example, if you have a fever infections increased white blood cells, hemoglobin is crowd and so on higher plateau, eliminate these needs from reagent and instrument and anticoagulation several aspects of consideration, anticoagulation is bad to can cause classification and platelet heighten, serious (wrong with anticoagulants) will lead to the red and white blood cells of increased reagent bad is wrong with the general dilute and let blood agent, the instrument itself usually won’t cause on the high side, unless the path of adjustment error or calibration coefficient was wrong to change.

Second, count is low, general is blocking the hole, the negative pressure is insufficient, factors such as pipeline leak, plugging the holes in some machines on the low average between one-third and two-thirds, under a microscope could see deposit around holes, need soaking or other treatment, remove the small holes to pay attention, installation must be careful not to crowded broken holes, in the hemoglobin than color and count the separation of the pool the apparatus, can be in high concentrations in the pool for cleaning operations, because don’t have to worry about counting pool pervious to light quality, but in the hemoglobin than color and the cell count pool as one of the machines, try not to do so, can take will come down hole soak, lest affect count pool pervious to light quality, cause abnormal hemoglobin.

Third, counting is not stable, this kind of situation first check whether sample system by itself is not accurate sample, pure white blood cells of the instability, first consider the problem of hemolysis agent, is late, and whether it the instrument matching, reagent and fluid amount is stable (also is check hemolysis agent with the sample system are in good condition); Pure red blood cell count of instability, want to consider the second dilute add fluid quantity problem. Of course, in the above problem analysis before, be the first to ensure that count pool and pipeline no problem. Added a bit, because of the mixed with white liquid play bubbles way, if in count process, playing the bubble switch valve doesn’t close tightly, leak phenomenon, it will cause count unstable, and in the course of maintenance to watch.

Forth, repeatability of the poor, the first to consider the above reasons, secondly, the adjustment of the gain or sensitivity is bad, will cause the linear  of thehematology analyzer becomes poor, repeatability becomes poor.

 

 

Article : From Perlong medical (http://www.pl999.net/)
Attention:If you want to copy, please attach the website.